Meter run unit (included into the Oil custody transfer metering system)
PURPOSE:
Meter run unit is an integral part of Oil custody transfer metering system and provide commercial accounting of hydrocarbons onsite.
Standard composition of Meter run unit:
-
Inlet and outlet headers;
-
Sensing lines (operating and spare);
- Closed drain line.
Standard composition of a sensing line with volume flow rate transducer :
-
valve or ball valve at the inlet of the line;
-
fine filter with quick disconnect cap, drain and air cocks (if a separate filter unit is not provided);
-
volume flow rate transducer;
-
a valve or ball valve with ensured closing of flow and control over the leakages at the outlet of the line;
-
a valve or ball valve with ensured shutting down of the flow and control over leakages at the outlet or inlet;
-
a flow regulating device at the outlet of sensing line, if required;
-
temperature transducer and temperature gage;
-
pressure gage and pressure transducer;
-
ball valve for drainage;
-
air operated ball valve at the inlet of a line (if no filter on sensing line);
Standard composition of a sensing line with volume flow rate transducer (coriolis acceleration flowmeter):
-
isolation valve at the inlet of a line;
-
fine filter with quick disconnect cap, drain and air cocks (if a separate filter unit is not provided);
-
volume flow rate transducer;
-
temperature transducer and temperature gage;
-
flow regulator at the outlet of a line;
-
pressure transducer and pressure gage;
-
isolation valve with ensured shutting down of the flow and control over leakages at the outlet at the outlet of a line towards a header and to calibration rig;
-
ball valve for draining;
- ball valve to be place in upper point of sensing line.