Dag 510 gas analyzer

PURPOSE AND APPLICATION AREA

Gas analyzers "DAG-510" are designed for:

• measurement of oxygen (O2), carbon monoxide (CO), nitrogen oxide (NO), nitrogen dioxide (NO2), sulfur dioxide (SO2), hydrogen sulfide (H2S) and hydrocarbons (methane or propane) in the off-gas of fuel-burning plants;

• temperature measurements at the sampling point and ambient temperature;

• measurement of absolute pressure, pressure difference;

• determination by the calculation method in accordance with GOST 17.2.4.06-90 of the speed and flow rate of gas-dust flows when working with a measuring probe - pneumometric tube Pitot or NIIOGAZ;

• determination by calculation method of carbon dioxide (CO2) and the amount of nitrogen oxides (NOX);

• Determination of the technological parameters of the fuel-burning plants by the calculation method - the excess air factor and the heat loss coefficient.

The field of application of gas analyzers is the control of the content of pollutants in the off-gases of stationary and mobile sources of industrial emissions for the purpose of ecological control and optimization of the combustion process of fuel. 

DESCRIPTION

The gas analyzer "DAG-510" (hereinafter - gas analyzer) is an automatic multifunctional portable device.

The gas analyzer is produced in six modifications, differing from each other in the list of the components to be determined, measuring ranges.

Depending on the modification, the gas analyzer is equipped with either a probe with a heated sampling hose and a sample preparation unit "BPP-510", or a probe with a connecting hose and a condensate collector.

 

The principle of the gas analyzer is based on the use of a set of electrochemical measuring sensors for measuring O2, CO, NO, NO2, SO2, and H2S contents of an infrared optical sensor for measuring hydrocarbon content, a thermoelectric transducer for measuring gas flow temperature, semiconductor sensors for measuring ambient temperature , measurements of absolute pressure and pressure difference.

Structurally, the gas analyzer is made in a rectangular case, the front panel of which has a display, keyboard, thermal printer, one of the side panels connecting plug.

The power supply of the gas analyzer is carried out from the built-in rechargeable battery, the recharging of the battery is performed from a DC source with a voltage of 12V. The supply of the sample preparation unit is carried out from the AC voltage network.

The gas analyzer is equipped with an RS 232C interface and a memory for storing measurement results. 

MAIN TECHNICAL SPECIFICATIONS

1. The list of measured parameters, measuring ranges and limits of the permissible basic error of gas analyzers, depending on the modification, are given in Table 1.

 

Table 1

Determined component

Measuring range

Limits of the allowed basic error

Nominal price of the unit of the smallest category

Absolute

Relative

Modification «Dag-510-GV»

Carbon monoxide (CO)

0 – 40 000 ppm

± 100 ppm (0 – 1000 ppm)

± 10 % (1000 – 40 000 ppm)

1 ppm

Nitric oxide (NO)

0 – 2 000 ppm

± 25 ppm (0 – 250 ppm)

± 10 % (250 – 2 000 ppm)

1 ppm

Nitrogen dioxide (NO2)

0 – 400 ppm

± 10 ppm (0 – 100 ppm)

± 10 % (50 – 400 ppm)

1 ppm

Modification «Dag-510-GS»

Carbon monoxide (CO)

0 – 4 000 ppm

± 10 ppm (0 – 100 ppm)

± 10 % (100 – 4 000 ppm)

1 ppm

Nitric oxide (NO)

0 – 400 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 400 ppm)

1 ppm

Nitrogen dioxide (NO2)

0 – 200 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 200 ppm)

1 ppm

Modification «Dag-510-GH»

Carbon monoxide (CO)

0 – 400 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 400 ppm)

0,1 ppm

Nitric oxide (NO)

0 – 100 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 100 ppm)

0,1 ppm

Nitrogen dioxide (NO2)

0 – 50 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 50 ppm)

0,1 ppm

Modification «Dag-510-МВ»

Carbon monoxide (CO)

0 – 40 000 ppm

± 100 ppm (0 – 1000 ppm)

± 10%(1000 - 40 000 ppm)

1 ppm

Nitric oxide (NO)

0 – 2 000 ppm

± 25 ppm (0 – 250 ppm)

± 10 % (250 – 2 000 ppm)

1 ppm

Nitrogen dioxide (NO2)

± 10 ppm (0 – 100 ppm)

± 10 % (100 – 400 ppm)

1 ppm

Sulfuric anhydride (SO2)

0 – 2000 ppm

± 25 ppm (0 – 250 ppm)

± 10 % (250 – 2 000 ppm)

1 ppm

Hydrogen sulfide (H2S)

0 – 400 ppm

± 10 ppm (0 – 100 ppm)

± 10 % (100 – 400 ppm)

1 ppm

Modification «Dag-510-МС»

Carbon monoxide (CO)

0 – 4 000 ppm

± 10 ppm (0 – 100 ppm)

± 10 % (100 – 4 000 ppm)

1 ppm

Nitric oxide (NO)

0 – 400 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 400 ppm)

1 ppm

Nitrogen dioxide (NO2)

0 – 200 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 200 ppm)

1 ppm

Sulfuric anhydride (SO2)

0 – 400 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 400 ppm)

1 ppm

Hydrogen sulfide (H2S)

0 – 200 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 200 ppm)

1 ppm

Modification «Dag-510-МН»

Carbon monoxide (CO)

0 – 400 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 400 ppm)

0,1 ppm

Nitric oxide (NO)

0 – 100 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 100 ppm)

0,1 ppm

Nitrogen dioxide (NO2)

0 – 50 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 50 ppm)

0,1 ppm

Sulfuric anhydride (SO2)

0 – 50 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 50 ppm)

0,1 ppm

Hydrogen sulfide (H2S)

0 – 50 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 50 ppm)

0,1 ppm

The measured parameters common for all modifications

Oxygen (O2)

0 – 21 % об.

>± 0,25 % об.

0,01 % об.

Hydrocarbons (according to CH4 or C3H8) * <

0 – 5000 ppm

± 100 ppm (0 – 1000 ppm)

± 10 % (1000 – 5000 ppm)

1 ppm

Gas flow temperature

-20 – +800 оС

± 3 оС (-20 – +300 оС)

± 1 % (300 – 800 оС)

0,1 оС

Ambient temperature

0 – 50 оС

± 1 оС

0,1 оС

Absolute pressure *

80,0 - 110,0 кПа

± 1 кПа

10 Pа

Differential pressure *

± (0–2,5) kPa

± 0,025 kPа

0,1 Pа

Gas flow rate *

Not standardized (Determination by calculation)

Carbon dioxide (CO2)

The sum of nitrogen oxides (NOX)

Coefficient of excess air

Heat loss factor

Note - Measured channels marked with "*" are installed on a separate order.

 

2. The limit of the allowed variation of the readings, in fractions of the limit of the permissible basic error of 0.5

3. The limit of the allowed total additional error from the change in the content of permissible non-measurable components of the analyzed gas mixture, in fractions of the limit of the permissible basic error of 0.5

4. The limit of the permissible additional error from the change in the moisture content of the analyzed gas mixture, in fractions of the limit of the permissible basic error of 0.5

5. The maximum flow rate of the analyzed gas mixture, l / min, not more than 1.5

6. Warm-up time, min, not more than 10

7. Settling time, s, no more than 300

8. Interval of working time without correction of indications, h, not less than 1000

9. Supply voltage:

• gas analyzer, V (12 ± 2)

• Sample preparation unit, B (220)

10. Network frequency, Hz (50 ± 1)

11. Power consumption:

• gas analyzer, W, not more than 20

• Sample preparation unit, W, not more than 500

12. Overall dimensions:

• gas analyzer, mm, no more than 280 х 120 х 120

• Sample preparation unit, mm not more than 280 х 250 х 210

13. Weight:

• gas analyzer, kg, not more than 3

• Sample preparation unit, kg, not more than 12

14. Mean time between failures, hour, not less than 10000

15. Average service life, years, not less than 8

16. Operating conditions:

• Operating temperature range, оС 5 - 40

• relative humidity at 30 ° C,% 10 - 75

• atmospheric pressure, kPa 84.0 - 106.7

• maximum amplitude of vibration (with frequency from 5 to 35 Hz), mm 0,35

• environment non-explosive

Определяемый компонент

Диапазонизмерений

Пределы допускаемой основной погрешности

Номинальная цена единицы наименьшего разряда

абсолютной

относительной

Модификация «ДАГ-510-ГВ»

Оксид углерода (CO)

0 – 40 000 ppm

± 100 ppm (0 – 1000 ppm)

± 10 % (1000 – 40 000 ppm)

1 ppm

Оксид азота (NO)

0 – 2 000 ppm

± 25 ppm (0 – 250 ppm)

± 10 % (250 – 2 000 ppm)

1 ppm

Диоксид азота (NO2)

0 – 400 ppm

± 10 ppm (0 – 100 ppm)

± 10 % (50 – 400 ppm)

1 ppm

Модификация «ДАГ-510-ГС»

Оксид углерода (CO)

0 – 4 000 ppm

± 10 ppm (0 – 100 ppm)

± 10 % (100 – 4 000 ppm)

1 ppm

Оксид азота (NO)

0 – 400 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 400 ppm)

1 ppm

Диоксид азота (NO2)

0 – 200 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 200 ppm)

1 ppm

Модификация «ДАГ-510-ГН»

Оксид углерода (CO)

0 – 400 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 400 ppm)

0,1 ppm

Оксид азота (NO)

0 – 100 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 100 ppm)

0,1 ppm

Диоксид азота (NO2)

0 – 50 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 50 ppm)

0,1 ppm

Модификация «ДАГ-510-МВ»

Оксид углерода (CO)

0 – 40 000 ppm

± 100 ppm (0 – 1000 ppm)

± 10%(1000 - 40 000 ppm)

1 ppm

Оксид азота (NO)

0 – 2 000 ppm

± 25 ppm (0 – 250 ppm)

± 10 % (250 – 2 000 ppm)

1 ppm

Диоксид азота (NO2)

± 10 ppm (0 – 100 ppm)

± 10 % (100 – 400 ppm)

1 ppm

Сернистый ангидрид (SO2)

0 – 2000 ppm

± 25 ppm (0 – 250 ppm)

± 10 % (250 – 2 000 ppm)

1 ppm

Сероводород (H2S)

0 – 400 ppm

± 10 ppm (0 – 100 ppm)

± 10 % (100 – 400 ppm)

1 ppm

Модификация «ДАГ-510-МС»

Оксид углерода (CO)

0 – 4 000 ppm

± 10 ppm (0 – 100 ppm)

± 10 % (100 – 4 000 ppm)

1 ppm

Оксид азота (NO)

0 – 400 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 400 ppm)

1 ppm

Диоксид азота (NO2)

0 – 200 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 200 ppm)

1 ppm

Сернистый ангидрид (SO2)

0 – 400 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 400 ppm)

1 ppm

Сероводород (H2S)

0 – 200 ppm

± 5 ppm (0 – 50 ppm)

± 10 % (50 – 200 ppm)

1 ppm

Модификация «ДАГ-510-МН»

Оксид углерода (CO)

0 – 400 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 400 ppm)

0,1 ppm

Оксид азота (NO)

0 – 100 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 100 ppm)

0,1 ppm

Диоксид азота (NO2)

0 – 50 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 50 ppm)

0,1 ppm

Сернистый ангидрид (SO2)

0 – 50 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 50 ppm)

0,1 ppm

Сероводород (H2S)

0 – 50 ppm

± 1 ppm (0 – 10 ppm)

± 10 % (10 – 50 ppm)

0,1 ppm

Измеряемые параметры общие для всех модификаций

Кислород (O2)

0 – 21 % об.

>± 0,25 % об.

0,01 % об.

Углеводороды (по СН4 или С3Н8)*<

0 – 5000 ppm

± 100 ppm (0 – 1000 ppm)

± 10 % (1000 – 5000 ppm)

1 ppm

Температура газового потока

-20 – +800 оС

± 3 оС (-20 – +300 оС)

± 1 % (300 – 800 оС)

0,1 оС

Температура окружающей среды

0 – 50 оС

± 1 оС

0,1 оС

Абсолютное давление *

80,0 - 110,0 кПа

± 1 кПа

10 Па

Разность давлений *

± (0–2,5) кПа

± 0,025 кПа

0,1 Па

Скорость газового потока *

не нормированы (определение по расчету)

Диоксид углерода (CO2)

Сумма оксидов азота (NOX)

Коэффициент избытка воздуха

Коэффициент потерь тепла


Примечание – Отмеченные знаком «*» измерительные каналы устанавливаются по отдельному заказу.

2. Предел допускаемой вариации показаний, в долях предела допускаемой основной погрешности  0,5

3. Предел допускаемой суммарной дополнительной погрешности от изменения содержания допустимых неизмеряемых компонентов анализируемой газовой смеси, в долях предела допускаемой основной погрешности   0,5

4. Предел допускаемой дополнительной погрешности от изменения влагосодержания анализируемой газовой смеси, в долях предела допускаемой основной погрешности   0,5

5. Максимальный расход анализируемой газовой смеси, л/мин, не более  1,5

6. Время прогрева, мин, не более  10

7. Время установления показаний, с, не более  300

8. Интервал  времени  работы  без  корректировки показаний, ч, не менее  1000

9. Напряжение питания:

  • газоанализатора, В  (12 ±2)

  • блока подготовки пробы, В  (220)

10. Частота сети, Гц  (50 ±1)

11. Потребляемая мощность:

  • газоанализатора, Вт, не более  20

  • блока подготовки пробы, Вт, не более  500

12. Габаритные размеры:

  • газоанализатора, мм, не более   280 х 120 х 120

  • блока подготовки пробы, мм не более  280 х 250 х 210

13. Масса:

  • газоанализатора, кг, не более  3

  • блока подготовки пробы, кг, не более  12

14. Средняя наработка на отказ, час, не менее  10000

15. Средний  срок службы, лет, не менее  8

16. Условия эксплуатации:

  • относительная влажность при температуре 30 оС, %  10 - 75

  • атмосферное давление, кПа   84,0 - 106,7

  • максимальная амплитуда вибрации (с частотой от 5 до 35 Гц), мм  0,35

  • окружающая среда  невзрывоопасная