Gas analyzer Vario Plus Industriall
Device Type: Portable
Measurements: O2 / CO / NO / NO2 / SO2 / H2S / CO2 / CH4 / C3H8 / H2 / Temperature / Diff. Pressure / m / s
With the possibility of operation in a semi-stationary mode
• The most accurate gas analyzer in its class!
• Ideal device for ecologists and technologists.
• Number of sensors: 2 to 9 - O2, CO, NO, NO2, SO2, H2S, H2, CH4 or C3H8, temperature, pressure / discharge, differential pressure, + CO2 calculation, alpha, efficiency, flow rate, Mass emissions.
• Up to 6 electrochemical sensors (O2, CO, NO, NO2, SO2, H2S).
• Up to 3 infrared NDIR sensors (O2, CO, CH4 or C3H8).
• Graphic display with backlight (Russian +14 languages) with "ZOOM" function, built-in high-speed printer, gas cooler (Peltier) with automatic condensate removal, memory for 8500 blocks, outputs to PC. Included: built-in batteries, mains adapter, rugged housing, modular gas sampling probe, spare filters, leather trunk.
The universal gas analyzer MRU Vario Plus Industrial is a multicomponent measuring modular system.
This means that this analyzer can be used as a mobile with autonomous power supply, as an accurate instrument for long-term measurements. If necessary, it is possible to use the MRU Vario Plus Industrial in a semi-stationary automatic measurement mode. It is intended for conducting routine tests, measuring Mass emissions, especially recommended for measurements in gas turbines.
Advantages:
• Use of infrared (NDIR) and electrochemical sensors
• Measurement of 9 gases simultaneously (3 infrared + up to 6 electrochemical)
• Graphic display with backlight (Russian +14 languages) with "ZOOM" function
• Operation in automatic measurement mode
• Built-in gas cooler (Peltier) with automatic condensate removal
Gas temperature measurement up to 1700 ° C
• 8 programmable analog outputs 4 ... 20mA
• Ability to work with heated gas lines
• Allows you to work with the remote control
• Long service life
• Designed for active use
• Pressure / discharge / differential pressure measurement
• High-speed printer without carriage (print time 3 sec)
• Very robust case with carrying strap
• Suitable for all types of burners
• Easy to use
• Different lengths and material of probes
• Russian version of the on-screen menu of the device
• Built-in memory for 8500 measurements
• RS 232 interface for data transfer to a PC
Specifications: |
||
Electrochemical sensors |
Measured values |
Limits of permissible errors |
O2 |
Measurement range: |
0 - 21,0 % |
Measurement error: |
± 0,2 % абс. |
|
CO(с H2компенсацией) |
Measurement range: |
0 - 4.000 ppm, Overload to 10.000 ppm |
Measurement error: |
± 20 ppm or 5 % from m.value / > 4.000 ppm 10 % from m.value / > 4.000 ppm |
|
CO very high (option) |
Measurement range: |
0 - 40.000 ppm, overload to 100.000 ppm |
Measurement error: |
± 200 ppm or 5 % from m.value / > 40.000 ppm 10 % from m.value / > 40.000 ppm |
|
NO (option) |
Measurement range: |
0 - 1.000 ppm, overload to 5.000 ppm |
Measurement error: |
± 5 ppm or 5 % from m.value / > 1.000 ppm 10 % from m.value / > 1.000 ppm |
|
NO2 (option) |
Measurement range: |
0 - 200 ppm, перегрузка до 1.000 ppm |
Measurement error: |
± 5 ppm or 5 % from m.value / > 200 ppm 10 % from m.value / > 200 ppm |
|
SO2 (option) |
Measurement range: |
0 - 2.000 ppm, overload to 5.000 ppm |
Measurement error: |
± 10 ppm or 5 % from m.value / > 2000 ppm |
|
H2S (option) |
Measurement range: |
0 - 50 ppm, overload to 500 ppm |
Measurement error: |
± 5 ppm or 5 % from m.value / < 50 ppm |
|
H2 (option) |
Measurement range: |
0 - 1%, overload to 2% |
Measurement error: |
± 0,02% or 5 % from m.value / < 1% 10 % from m.value / > 1% |
|
With multi-gas IR module |
||
CO |
Measurement range: |
min. 0 - 10.000 ppm to max. 0 - 30 % |
Measurement error: |
± 40 ppm or 5 % from m.value |
|
CO2 |
Measurement range: |
min. 0 - 3 % to max. 0 -30 % |
Measurement error: |
± 0,50 % or 5 % from m.value |
|
CXHY as C3H8 |
Measurement range: |
min. 0 - 10.000 ppm to max. 0 - 5 % as C3H8 |
Measurement error: |
± 20ppm or 5% from m.value |
|
CXHY as CH4 |
Measurement range: |
min. 0 - 10.000 ppm to max. 0 - 5 % as CH4 |
Measurement error: |
± 60 ppm or 5% from m.value |
|
Flue gas temperature TA |
Measurement range: |
0 - 650 °C Stainless steel probe |
Measurement error: |
0 - 1.100 °C Inconel alloy probe |
|
Measurement range: |
0 - 1.750 °C with ceramic probe |
|
Measurement error: |
± 2 °C / < 200 °C 1 % from m.value > 200 °C |
|
Combustion temperature TL |
Measurement range: |
0 - 100 °C |
Measurement error: |
± 1 °C |
|
Draft / depression |
Measurement range: |
± 100 hPа |
Measurement error: |
± 0,03 hPа or 1% from m.value |
|
Differential pressure |
Measurement range: |
± 100 hPа |
Measurement error: |
± 0,03 hPа or 1% from m.value |
|
Gas flow rate (with Pitot tube) |
Measurement range: |
1 m/s to 100 м/с |
Measurement error: |
± 1 m/s or 1 % from m.value |
|
Mass emissions: |
g/ s, ... |
|
Estimated values: (Dependent on the type of fuel) |
||
CO2 (Estimated for an unidentified direct measurement of CO2 (calculation is based on the selected fuel type and the measured value of O2) |
Measurement range: |
0 - CO2 max |
Dew point: |
°C |
|
Losses with flue gases qA: |
0 - 99,9 % |
|
Efficiency ή: |
0 - 120 % |
|
Dimension of measurement data: |
mg/Нm3, Relative to O2, mg / kWh, NOx as mg / Nm3NO2, mg / s. |
Common data: |
|
Operation temperature: |
+ 5 - + 45 °C, max. 95 % without condensation |
Storage temperature: |
- 20 - + 50 °C |
Supply voltage: |
Net 110 - 230 Vac, 50/60 Hz 12 V / 1,8 Ah with internal battery, 2 hours of operation |
Protection class: |
IP 21 |
Weight: |
About 7.000 g (without bag and accessories) |
Dimensions: |
530 x 490 x 310 mm |