Gas analyzer portable Optima 7

Main features:

Device type: Portable

Measurements: O2 / CO / NO / NO2 / SO2 / H2S / CO2 / CH4 / C3H8 / Temperature / Delta P /m / s

COMPACT HIGH-SPEED GAS-ANALYZER

О2 Sensors (Long Life) up to 6 years

Electrochemical sensors O2 and CO with H2 compensation

Ability to install IR sensors

Number of gases simultaneously: from 1 to 7 - to choose from (O2, CO, NO, NO2, SO2, H2S, CH4, CO2) + temperature + pressure / discharge + differential pressure + CO2 calculation, alpha, EFFICIENCY + Flow + measurement of gas flow rate

Advantages:

• Comfortable durable and lightweight case (800g)

• Measurement of 1 to 7 types of gases simultaneously

• Up to 3 CO channels with auto-switching: CO low → CO → COhigh.

• Up to 2 NO channels with auto-switching: NO low → NO

• Very high official measurement accuracy in the Russian Federation from ± 5 ppm

• Recommendations for use from the Research Institute "Atmosphere"

• Possibility of official measurements in winter to - 30 ° C!

• Thrust / pressure / diff. Pressure / gas flow rate

• Optional pump for purging the CO sensor

• Suitable for all types of boilers and turbines

• Gas sampling probes up to 2 meters long at temperatures up to 1700 ° С

• Multi-lingual version of the device's on-screen menu

• The possibility of simultaneous indication in ppm and mg

• Memory 16000 blocks + SD card for 2 GB (data in Excel format !!!)

• Mini USB interface for transferring data to a PC and charging batteries

• Operation from built-in batteries up to 15 hours or from a 220 V network

• Condensate collector with stainless steel elements

• Connectors made of stainless steel

• Infrared interface for data transfer to a portable high-speed IR

• Thermal printer (optional printer)

 

High-speed graphic IR Thermal printer (optional). High speed printing (about 2 seconds per report). The usual thermal paper is used (it is used in cash registers ∅46mm width 57mm.). Easy paper replacement. 4x1600 mAh NI-MH battery is used with the ability to charge from a mini-USB cable.

Anti-impact thermocover (thermobox) for gas analyzer operation in frosty weather:

Up to -15 ° C without internal heating function up to -30 ° C with internal heating function

Created specifically to facilitate measurements in frosty weather. Use of the cover allows not only to work in winter, incl. in hard-to-reach places, but also give the measurements an OFFICIAL status.

Specifications:

 

Gas measurement channels

Measurement range of volume fraction

Limits of permissible error

absolute

relative, %

О2 channel

(0 ― 21,0) %

± 0,2 %

-

CO channel (low to 300 ppm-1)

(0 ― 100) ppm-1
(св. 100 ― 300)ppm-1

± 5 ppm-1

± 5

CO channel (to 10000 ppm-1)

(0 ― 400) ppm-1
(св. 400 ― 10000) ppm-1

± 20 ppm-1

± 5

COchannel (to10000 ppm-1), when installed channel CO (low 300 ppm-1)

(св. 300- 400) ppm-1
(св. 400 ― 10000) ppm-1

± 20 ppm-1

± 5

CO channel (high to 20000 ppm-1)

(0 ― 800)ppm-1
(св. 800 -4000) ppm-1
(св. 4000 ― 20000) ppm-1

± 40 ppm-1

± 5 ± 10

COchannel (very high to 10 %)

(0 ― 0,4) % (св. 0,4 ― 10) %

± 0,02 %

± 10

NO channel (low to 300 ppm-1)

(0 ― 50)ppm-1
(св. 50 ― 100)ppm-1
(св.100-300) ppm-1

± 5 ppm-1
± 10ppm-1

± 10

NO channel (to 4000 ppm-1)

(0 ― 100)ppm-1
(св.100 ― 4000) ppm-1

± 10 ppm-1

± 10

NO channel (to 4000 ppm-1), when installed channel NO (low 300 ppm-1)

(св.300 ― 4000) ppm-1

 

± 10

NO2 channel (до 500 ppm-1)

(0 ― 50) ppm-1
(св. 50 ― 100) ppm-1
(св. 100 ― 500) ppm-1

± 5 ppm-1
± 10 мppmлн-1

± 10

SO2 channel (to 4000 ppm-1)

(0 ― 100) ppm-1
(св. 100 ― 4000) ppm-1

± 10 ppm-1

± 10

H2S channel (to 300 ppm-1)

(0 ― 100) ppm-1
(св. 100 ― 300) ppm-1

± 10 ppm-1

± 20

СО2 channel infrared (20 %)

(0 ― 10) %
(св. 10 ― 20) %

± 0,5 %

± 5

 

Temperature measurement channels

Temperature measurement ranges

Limits of permissible error

absolute

relative, %

(0 -650)оС (Stainless steel probe, thermocouple type K)

from 0 to + 200 оС
higher + 200 to650оС

± 2 оС

± 1

(0 -1000)оС Probe made of INCONEL alloy, thermocouple type K)

to + 200 оС
higher + 200 оС

± 2 оС

± 1

Air temperature 0 ... 100 оС (stainless steel probe, thermocouple type К)

to + 100 оС

± 1 оС.

 

 

Pressure measurement channels

Measurement range of differential pressure, overpressure, vacuum pressure

Limits of permissible error

absolute

relative, %

From minus 2 hPа ...to 2hPа
From minus 100hPа...to minus 2hPа
from 2hPа...to 100hPа

± 0,02 hPа

± 1

 

Additional specifications

Parameter

Description

Ambient temperature, ° C:

From 5 ... to 45

From minus 15 to 40 (with a thermocouple)

From minus 30 to 40 (with thermobox)

Relative humidity, %:

Up to 95, without condensation

Storage temperature, ° C:

From minus 20 to 50

Power supply:

Built-in battery, from an external 220 V source or from a USB port of a computer

Power consumption, W, not more:

7 W (with 18 W thermobox)

Protection class:

IP 20 (with thermobox I P 21)

Dimensions, mm, not more than:

244x113x54(With thermobox 292x150x68)

Weight, kg, not more:

0,9 kg, with a thermocouple 1,2 kg, with thermobox 2,7 kg