AL 2021 - Continuous Hydrogen Peroxide (h2o2) analyser for air and water samples

AL2021 Features:

·         Continuous online monitoring of H2O2 with unique sensitivity of 100ppt

·         Provides absolute concentrations for H2O2 and relative values for other peroxides

·         Analysis of gaseous and liquid samples with only one instrument

·         H2O2 concentration readings within minutes

·         Designed for climate research, environmental air monitoring and indoor air quality control

·         Perfectly suited for monitoring H2O2 during decontamination procedures

 

 

 

 

 

 

 

 

The H2O2 monitor AL2021 from Aero-Laser has an extraordinary high sensitivity and a unique low detection limit of 100ppt (parts per trillion) for gaseous samples and 100 ng/liter (eq. 2x10-9 molar) for liquid samples, respectively. The complete chemical processing, including gas stripping, is integrated into the instrument.

The detection technique is based on an enzymatic peroxidise reaction, which is not only sensitive for H2O2, but also for other peroxides. Hence, after stripping the sample gas, the aqueous solution is separated in two channels. In channel A the concentration of all peroxides is measured, while H2O2 is selectively destroyed in channel B by the enzyme catalase. The absolute concentration of H2O2 is further calculated from the difference of the signals of both channels. These signals are obtained by exciting the products of the peroxidase reactions with UV light and detecting the fluorescent light by photomultipliers. With this method an extraordinary selectivity is achieved, avoiding interferences from other substances. The AL2021 is the only instrument worldwide providing continuous concentrations ofH2O2 in the range around and below 1ppb.

The AL2021 was originally developed for environmental and climate research and is employed worldwide in atmospheric monitoring stations. Since H2O2 is getting more and more important in the field of sterilisation and decontamination, the instrument is widely used by the pharmaceutical industry for controlling of the atmosphere inside filling systems.

Specifications:

H2O2 detection technique                                             

Fluorimetric, using an enzymatic reaction (peroxidase)

Linear detection range                           

 

            0.1ppb to 3000ppb (gaseous), 100ng/liter - 3mg/liter (liquid)

Detection limit                                                 

 

100ppt (gaseous), 100ng/liter eq. 2x10 9 molar (liquid)

Time resolution and delay                                             

90sec (10% - 90%), ~300sec delay 2% full scale 0°C to +40°C

Noise                                      

Sample gas temperature 

Calibration and zeroing

2% full scale

0 C to +40 C

Automatic zeroing and semi-automatic calibration using liquid standards or automatic calibration using internal gas generator (optional)

Operation                                                        

Front panel and remote software via RS-232

Data output                                                     

On display or via RS-232 interface

(SQL-based graphic data logging software available)

Weight and dimensions                         

20kg, fit for 19" rack (whd: 45cm x 19cm x 56cm)

Power requirements                                          

110VAC / 220VAC, 110W, 24VDC on request